• Precise—High collection rates without compromising CVs
• Faster—Rare even detection in dramatically reduced acquistion times
• Simple—Run samples without red blood cell (RBC) lysis or washing
(minimizes cell loss)
• Accurate—Directly measure absolute cell counts without the use of beads
• Flexible laser configuration (blue/violet or red/blue) for 6 color
combinations
Rare Event Detection in Dramatically Reduced Acquisition Times
The Attune® Acoustic Focusing Cytometer is designed to collect up to 20 million events per run. The Attune® Acoustic Focusing Cytometer uses an innovative technology that exploits the physical difference between cells or particles relative to the background medium, allowing adjustable collection rates ranging from 25 µL/min to 1000 µL/min, which is nearly an order of magnitude higher than a conventional flow cytometer. The time required to acquire 1 million events using a hydrodynamic flow cytometer with a HIGH (120 µL/min) flow rate, which is the least sensitive mode and Attune® cytometer at different collection rate is listed in the table below:
Acquisition Times on Hydronamic vs. Acoustic Focusing Cytometers
| Instrument/Collection Rate | Time to Acquire 1 Million Granulocyte Events | Relative Rate |
| Hydrodynamic focusing/HIGH flow rate | 63 min 33 sec | — |
| Acoustic focusing at 200 µL/min | 13 min 20 sec | 4.8 times faster |
| Acoustic focusing at 500 µL/min | 5 min 47 sec | 11.0 times faster |
| Acoustic focusing at 1,000 µL/min | 3 min 13 sec | 19.7 times faster |
| Acoustic focusing at 1,000 µL/min | 3 min 13 sec | 19.7 times faster |
The Attune® Acoustic cytometer achieves sample throughput at rates over 10 times faster than other cytometers—up to 1,000 µL per minute, enabling rapid detection of rare events with a reliable measure of accuracy without aborting any data.
High Collection Rates Without Compromising CVs
Traditional flow cytometers utilize hydrodynamic focusing that wraps an inner sample core with a outer layer of sheath fluid to align the cells. As the sample introduction increases, the sample core stream widens and cells become less focused resulting in increased variability of signal. In the Attune® Acoustic Focusing Cytometer, the cell alignment is maintained in the precise center of the sample stream even as the sample stream widens with the increased rate of sample introduction. This tight alignment results in:
• Improved data quality by minimizing variability as cells pass through laser
• Reduced CVs, leading to better resolution
• Increased sensitivity achieved with variable flow rates that allow longer laser dwell times
Simplify Sample Preparation—Maximize Efficiency
Traditional flow cytometers rely on a large volume of fluid to focus cells, limiting the amount of sample that can be used. This often means that cells must be prepared or concentrated prior to analysis on those types of instruments. The Attune® Acoustic Focusing Cytometer offers flexibility in the sample concentration that can be analyzed. Acoustic focusing enables:
• Elimination of concentration steps
• Effective background fluorescence reduction by a simple dilution step, eliminating the need to wash fluorescence samples before analysis
• No-lyse/no-wash assays
• Analysis of samples that have low cell numbers including CSF, stem cells, mouse bone marrow, mouse blood, and thin needle aspirates
• Acquisition of high-volume of samples in minimal time
• Analysis of complete sample without sample loss
Directly Measure Absolute Counts Without the Use of Beads
The Attune® Acoustic Focusing Cytometer uses accurate syringe pumps to measure the exact volume of sample analyzed during data collection. Using this information, the Attune® cytometer is able to directly measure absolute cell numbers without the need for beads, which minimizes the amount of sample required and helps reduce the costs associated with the assay.
How Acoustic Focusing Works
The Attune® Acoustic Focusing Cytometer is the first cytometer that uses ultrasonic waves (over 2 MHz, similar to those used in medical imaging) to position cells into a single, focused line along the central axis of a capillary.
Acoustic focusing is largely independent of the sample input rate, enabling cells in the Attune® Acoustic Focusing Cytometer to be tightly focused at the point of laser interrogation, regardless of the sample-to-sheath ratio. This, in turn, allows cell velocity to be slowed so that more photons are collected, giving you high-precision analysis at unprecedented volumetric sample throughput.
Extensive Support Organization
With over 2,000 global service and support personnel, Applied Biosystems has the most extensive network of experienced Field Application Specialists (FAS) and Support Engineers available. For our Attune® Acoustic Focusing Cytometer users, we offer a dedicated team of engineers, application specialists, and informatics support staff, ready to support you. The Attune® cytometer is fully supported for one year with our extensive service plan, which includes:
• Comprehensive training
• Application and assay support
• Worldwide technical service
Extended service plans are also available. Visit the Attune® Acoustic Focusing Cytometer overview page for more information detailing available service plans, and other helpful data and videos.